Dripping hose with labyrinth Pluvio Tape < ATP
Dripping hose with labyrinth Pluvio Tape < ATP
Dripping hose made on low-thickness flexible pipe made of top quality polyethylene, with continuous labyrinth with fast water jets. Pluvio Tape represents the most advanced technological solution in drip irrigation.
The labyrinth is welded during the extrusion phase and the water outlet hole is made with a linear cut that opens when the hose is under pressure and closes at the end of the irrigation cycle, avoiding the entry of foreign particles into the labyrinth. The labyrinth profile is designed to create fast water jets that ensure high flow uniformity and an excellent coefficient of production variation (CV). It is ideal in cases of very close plant sixths, sandy and very draining soils thanks to the presence of drop points with reduced spacing, and light sub-irrigation systems.
Lfsprrain Product Page
We recommend the use of the Pluvio Tape dripping hose in case of very short spacing.
Average relative flow of single-wing labyrinth drip irrigation tape ...
Materials
A single-wing labyrinth drip irrigation belt produced by a water-saving irrigation company widely used in China was selected for experiments. The rated flow rates of the drip irrigation belts produced by this company are 1.8, 2.4, 2.6, 2.8, and 3.2 L/h, and drip irrigation belts with rated flow rates of 1.8, 2.6, and 3.2 L/h were selected for study. The structural parameters of these three types of single-wing labyrinth drip irrigation belts are shown in Fig. 1, and the hydraulic performance parameters are shown in Table 1. The most commonly used potassium-sulfate-type compound fertilizer was chosen, which has the advantages of good water solubility, easy absorption, high nutrient content, few auxiliary components, and good physical properties; the nutrient content was N: P2O5: K2O = 17: 17: 17, and total nutrient content was greater than 51%.
The natural soil from Xishan, Urumqi, China, was used as the sediment, which was passed through a 120-mesh sieve. Then, the particle size was larger than 0.074 mm, a set of standard-sieve to sieve. Collect the sieve balance of each sieve, and weigh the particles to obtain the percentage of soil weight. Finally, the particle size was smaller than 0.074 mm, configured into a soil suspension with uniform concentration was prepared with a density meter at different times, and suspension densities were measured. According to the densitometer reading and soil particle subsidence time, the percentage of soil weight of particles was calculated, and finally the distribution curve of particle size was drawn as shown in Fig. 2. The proportion of particles with a size < 0.125 mm was 100%, and the proportion with a size < 0.1 mm accounted for 35.28%. The median grain size D50 was 0.106 mm.
A schematic of the test platform is shown in Fig. 3. This set of drip irrigation belt anti-clogging performance test bench models was KD-DJC, manufactured by Hebei Kedao Testing Machine Technology Co., Ltd., and the system is suitable for a voltage of 380 V. The main control cabinet includes a Xilin SD200 vector inverter, the highest frequency is 0–600 Hz, the load frequency is 2–10 kHz, and the speed regulation range is 1:50 or 1 Hz/150% rated torque. A 32CDLF4-150 light multi-stage pump, produced by Yongjia Yingke Pump Valve Co., Ltd., with a flow of 4 m3/h, speed of rpm, lift of 120 m, and power of 3 kW, was used. Also employed was a YE2-802-2 three-phase asynchronous motor, with a power of 11 kW, voltage of 380 V, frequency of 50 Hz, rotation speed of rpm. An IRK50-100A centrifugal pump with a flow rate of 22.3 m3/h, lift of 10 m, matching power of 1.1 kW, and rotation speed of rpm was also employed. The length of the drip irrigation tape test platform was 35 m.
Introduction to projection pursuit regression
PPR is a new and valuable new technology developed by the international statistical community in the mid-s. It is an interdisciplinary subject of statistics, applied mathematics, and computer technology. It uses computer technology to project high-dimensional data onto a low-dimensional subspace and finds a projection that can reflect the structure and characteristics of high-dimensional data by minimizing a certain projection index. It has the advantages of robustness, anti-interference, and high accuracy, so it is widely used in many fields. It has been applied to nonlinear function approximation and function smoothing, as well as to principal component and independent component analysis. It offers advantages in extracting the internal structural characteristics of high-dimensional data (e.g., influencing factors and degree of influence). Moreover, the PPR model has a higher accuracy than other models. In the PPR model, the sum of a series of ridge functions is used to approximate a regression function. The key to PPR is to estimate fi and to determine the optimal combination of αij and βi. If x is a P-dimensional independent variable and y the dependent variable23, then
$$\widehat{y} = E\left(y|x\right) = \overline{y }+\sum_{i = 1}^{M}{\beta }_{i}{f}_{i}\left(\sum_{j = 1}^{P}{\alpha }_{ij}{x}_{ij}\right)$$ (1)where Efi = 0, Efi2 = 1, \(\sum_{j = 1}^{P}{{\alpha }_{ij}^{2}}\)=1, fi is the ith ridge function, M and Mu are the upper limit and the optimal number of ridge functions, βi is the weight coefficient of a ridge function, αij is the ith component in the jth direction, and Q is the number of dependent variables.
The steps of solving the PPR model are the following:
-
1.
Select the initial projection direction α.
-
2.
Perform a linear projection on \({\left\{{X}_{i}\right\}}_{j}^{n}\) to obtain \({\alpha }^{T}{X}_{i}\), and perform a smoothing method on \(\left({\alpha }^{T}{X}_{i}, {Y}_{i}\right)\) to determine the ridge function \({f}_{\alpha }\left({\alpha }^{T}\right)X, i=1,\dots ,n\).
-
3.
Set the value of \({\sum_{i=1}^{n}\left({y}_{i}-{f}_{\alpha }\left({\alpha }^{T}{X}_{i}\right)\right)}^{2}\) that minimizes α as α1. Repeat Step (2) until the error does not change, and then determine α1 and \({f}_{1}\left({\alpha }_{1}^{T}X\right)\).
-
4.
Let the fitting residual of \({r}_{1}\left(X\right)=Y-{f}_{1}\left({\alpha }_{1}^{T}X\right)\) obtained from the first calculation replace Y. Repeat Steps (1)–(3) to obtain α2 and \({f}_{2}\left({\alpha }_{2}^{T}X\right)\).
-
5.
Repeat Step (4). Calculate \({r}_{2}\left(X\right)={r}_{1}\left(X\right)-{f}_{2}\left({\alpha }_{2}^{T}X\right)\) to replace \({r}_{1}\left(X\right)\) until the Mth \({\alpha }_{M}\) and \({f}_{M}\left({\alpha }_{M}^{T}X\right)\) are obtained and \(\sum_{i=1}^{n}{r}_{i}^{2}\) no longer decreases or a certain accuracy criterion is met.
-
6.
Determine the last mth α and f.
-
7.
Calculate \(\mathrm{f}\left(\mathrm{x}\right)=\sum_{\mathrm{m}-1}^{\mathrm{M}}{\mathrm{f}}_{\mathrm{m}}\left({\mathrm{\alpha }}_{\mathrm{m}}\mathrm{X}\right)\).
Uniform orthogonal test
According to the actual situation of irrigation water, the designed sediment content is 1, 2, and 3 g/L29. Three levels, i.e., 0.6, 1.8, and 3 g/L, were designed according to the actual irrigation fertilizer concentration. Low-pressure and small-flow drip irrigation technology is the most advanced drip irrigation technology at present. It has the characteristics of low working pressure, low operating energy consumption, low engineering investment, and good irrigation uniformity30. In this study, three gradients of operating pressures, i.e., 40, 70, and 100 kPa, were designed. The uniform orthogonal design table UL9 (33) for the three factors of fertilizer concentration, sediment content, and working pressure (marked E, S, and B, respectively) was used, as shown in Table 2.
Test results and model establishment
Twenty-five drippers for each drip irrigation tape were chosen, and a -mL water collection bucket was placed under them to collect water. To accelerate the test process, referring to the draft international dripper anti-clogging research standard, the irrigation period was shortened in equal proportions31. The selected irrigation time was 10 min, and the irrigation interval was 30 min. A total of nine irrigations were performed. After the irrigation was completed, two 15 min flow measurements were performed, and the average value taken. The dripper flow adopts the weighing method, and a model YP200N electronic balance (Shanghai Jinghai Instrument Co., Ltd., China) was used. Its maximum weight capacity is g and the division value is 0.01 g. Before the muddy water test started, clean water was added to the cleaned muddy water tank and the clean water flow measured under the current conditions. After the clean water test, the original arrangement was kept unchanged, and prepared sandy water with the corresponding concentration was added to the muddy water tank for flow measurement. After each group of treatments, the drip irrigation belt was replaced with a new one, and the system pipes, water tanks, and pumps were flushed.
In this study, the clogging of the drip irrigation system was determined based on the average relative flow, and the threshold was set to 0.. The equation for the calculation of average relative flow is
$$q = \frac{\sum_{1}^{N}\frac{{q}_{pi}}{{q}_{i}}}{N}$$ (2)where q is the average relative flow, i is the number of a dripper, N is the total number of drippers, qpi is the flow of the ith dripper in muddy water (L/h), and qi is the flow of the ith dripper in clean water (L/h).
Recommended article:Wholesale Multi-Sizes Waterproof Rubber Assorted O-Rings Gasket ...
4 Advice to Choose a ultrasonic water flow meter
The company is the world’s best Labyrinth Drip Tape(it,in,vi) supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.
The test was carried out strictly according to the test table of uniform orthogonal design, and the average relative flow under each muddy water condition calculated by Eq. (2); see Table 3 for details. A PPR model was established to analyze the 27 groups of average relative flow data in Table 3. The smooth coefficient of the projection sensitivity was 0.5, and the number of projections M was 5. Because Mu should be smaller than M, we set Mu to 3. The final modeling parameters were as follows: N = 9, P = 3, Q = 1, M = 5, Mu = 3.
Through PPR analysis, we obtained the weight coefficient β of the ridge function and the projection direction α of H1, H2, and H3, as in Eqs. (3)–(8). The vector formula of β and α of each factor were substituted into Eq. (1) to obtain the final calculation model, as follows:
$$\beta = \left(0.992, 0.140, 0.063\right)$$ (3) $$\left(\begin{array}{c}{\mathop{\alpha }\limits^{\rightharpoonup} }_{1}\\ {\mathop{\alpha }\limits^{\rightharpoonup} }_{2}\\ {\mathop{\alpha }\limits^{\rightharpoonup} }_{3}\end{array}\right) = \left(\begin{array}{ccc}-0.520& 0.489& 0.251\\ -0.854& 0.872& -0.968\\ -0.003& -0.040& -0.011\end{array}\right)$$ (4) $$\beta = \left(1.018, 0.150, 0.075\right)$$ (5) $$\left(\begin{array}{c}{\mathop{\alpha }\limits^{\rightharpoonup} }_{1}\\ {\mathop{\alpha }\limits^{\rightharpoonup} }_{2}\\ {\mathop{\alpha }\limits^{\rightharpoonup} }_{3}\end{array}\right) = \left(\begin{array}{ccc}-0.496& -0.124& 0.296\\ -0.868& 0.992& 0.954\\ -0.001& -0.028& 0.052\end{array}\right)$$ (6) $$\beta = \left(0.987, 0.234, 0.280\right)$$ (7) $$\left(\begin{array}{c}{\mathop{\alpha }\limits^{\rightharpoonup} }_{1}\\ {\mathop{\alpha }\limits^{\rightharpoonup} }_{2}\\ {\mathop{\alpha }\limits^{\rightharpoonup} }_{3}\end{array}\right) = \left(\begin{array}{ccc}-0.253& 0.489& 0.251\\ -0.967& 0.872& -0.968\\ 5.760& 0.002& -0.023\end{array}\right)$$ (8)Influences of the factors on average relative flow
The results of variance analysis are shown in Table 4. At a 95% confidence interval, the influences of fertilizer concentration and sediment content on the average relative flow of the H1 drip irrigation tape were significant, the influence of sediment content for the H2 drip irrigation tape was significant, and the influence of fertilizer concentration was important. For the H3 drip irrigation tape, the influence of sediment content was significant, and the influence of fertilizer concentration was important. In addition, the influence of operating pressure for none of the three types of drip irrigation tapes was crucial. These results suggested that fertilizer concentration and sediment content had a substantial influence on the relative flow of the dripper and were the key influencing factors of dripper clogging. In terms of the fertilizer concentration, its influence on the relative flow of H1 was significant, and the influence for H2 and H3 only reached the substantial level. Although all three types of drip irrigation tapes had single-wing labyrinth channels, H1 had a narrower channel compared with H2 and H3, which promoted the collision and flocculation of sediment particles to a certain extent, leading to a higher probability of stable agglomeration formation and dripper clogging. On the basis of the P values, the order of the influences of the factors on the average relative flow was sediment content > fertilizer concentration > operating pressure.
Moreover, the weight coefficient of the ridge function of each factor was calculated according to PPR, and the results are shown in Table 5. Based on the weights of the factors, the order of influences for H1, H2 and H3 is as follows: sediment content > fertilizer concentration > operating pressure. These results were consistent with the results of the variance analysis.
To summarize, the order of factors affecting the average relative flow of the single-wing labyrinth drip irrigation belt is sand content > chemical fertilizer concentration > working pressure. Sediment content is the main factor affecting the blockage of drip irrigation belts. It was found that particles with a particle size in the range 0.034–0.067 mm are difficult to flow out of the channel32, and the sediment in this range will form a film on the wall of the flow channel33. This will lead to a decrease in the average relative flow, and measures should be taken to reduce the sediment content in this particle size range during muddy water irrigation with integrated water and fertilizer. Fertilizer concentration is the second influencing factor. Potassium sulfate has an inhibitory effect on the ability of the dripper to transport sand34. It is easy to form the precipitation of sulfate through application of potassium sulfate fertilizer, and the adsorption of the precipitation on the wall of the capillary will increase the roughness of the wall of the drip irrigation belt. This will increase the probability of sediment particles colliding, thereby slowing the flow of water and making sediment particles more likely to settle35,36. Regarding sediment content > fertilizer concentration, fertilization will change the cation concentration in water, whereas most fine-grained sediments are negatively charged, and the cations compress the electric double layer structure on the surface of the sediment by neutralizing37. As a result, the electrostatic repulsion between sediment particles is reduced, which enhances flocculation of sediment, making it easier for the sediment to form a stable agglomeration structure to block the dripper38. When the actual sand content is large, the fertilization concentration should be reduced to reduce the occurrence of clogging.
PPR model evaluation
The error of the measured and predicted values of the average relative flow calculated and analyzed by the PPR program is shown in Table 6. The maximum relative errors of the average relative flow of H1, H2, and H3 were 1.24%, 1.07%, and 0.94%, respectively. When we used an absolute relative error of under 5% to calculate the pass rate of the modeling samples, the pass rate of nine testing datasets was 100%.
The three types of single-wing labyrinth drip irrigation belts with different flow rates have similar properties, and the amount of PPR modeling analysis data is large. Therefore, the H1-type drip irrigation belt was used to test the accuracy of the established PPR average relative flow prediction model. Nine groups of test samples were selected, and the comparison between the measured and predicted average relative flows is shown in Table 7. It can be seen from the table that the difference between the predicted value of the reserved test sample and the measured value was small, and the maximum relative error was 4.87%. When the absolute value of the relative error of under 5% was used to judge the pass rate of each modeling sample, the pass rate of the nine testing datasets was 100%.
The root mean square error (RMSE) is described as the root of the mean square error: the proportion of the sum of the square of the difference between estimated and actual values to the total number of observations. The equations are39
$$RMSE = \sqrt{\frac{\sum_{i = 1}^{n}{\left({A}_{i}-{F}_{i}\right)}^{2}}{n}}$$ (9) $$nRMSE = \frac{RMSE}{\overline{A} }\times 100\%$$ (10)where Ai is the actual value, Fi is the estimated value, n is the number of samples, RMSE is the root mean square error, \(\overline{A }\) is the average value of the actual data, and nRMSE is the ratio of the RMSE to the average value. To evaluate the performance of the models, the following criteria were introduced: (1) nRMSE < 10%, excellent; (2) 10% < nRMSE < 20%, good; (3) 20% < nRMSE < 30%, fair; and (4) nRMSE > 30%, poor26.
According to Eqs. (9) and (10), the average relative flow nonlinear model nRMSE of H1, H2, and H3 drip irrigation belts are 0.66%, 0.74%, and 0.34%, respectively, all of which less than 10%. In conclusion, the performance of the established PPR average relative flow model under muddy water conditions is excellent, indicating that the established PPR model has good stability and high accuracy.
Model simulation and optimization
Once the order of influence of the factors (i.e., fertilizer concentration, sediment content, and operating pressure) on the average relative flow was obtained, we then used the PPR model to find the internal structure of the data and calculated the average relative flow under different conditions. By fixing one factor and changing the other two, a contour plot of the average relative flow was obtained, as shown in Fig. 4.
In Fig. 4a, the average relative flow rate of the H1-type drip irrigation tape was reduced by 17.5%. It can be seen that under the condition of sand content of 1 g/L the average relative flow rate decreases faster in the range 40–100 kPa. Under the condition that the sand content remains unchanged, the increase in the fertilizer concentration can promote the clogging of the dripper. In Fig. 4b, the average relative flow decreased by 23.4%. In Fig. 4c, the average relative flow decreased by 32.34%, and the average relative flow decreased by 5.39% in the chemical fertilizer concentration range 0.6–3.0 g/L. Under the condition of pressure of 40 kPa, the effect of sediment content on the average relative flow is more significant than that of fertilizer concentration. From the comprehensive graph and analysis, it can be seen that the optimal operating conditions are as follows: the chemical fertilizer concentration is 0.6–1.2 g/L, the sand content is 1 g/L, and the value range of working pressure is 40–55 kPa.
In Fig. 5a, the average relative flow rate of the H2-type drip irrigation tape decreased by 12.53%. It can be seen that under the condition of 1-g/L sediment content, the pressure change in the range 40–100 kPa and the flow rate drop in the range of chemical fertilizer concentration from 0.6 to 3 g/L are smaller. In Fig. 5b, under the condition of a chemical fertilizer concentration of 0.6 g/L, the average relative flow decreased rapidly with increasing sediment content, and the decrease was 15.51%. In the pressure range 40–100 kPa, the average relative flow changed little, with a decrease of 6.02%. In Fig. 5(c), under the working pressure of 40 kPa, the average relative flow rate decreased by 29.6%. From the comprehensive graph and analysis, it can be seen that the optimal operating conditions are as follows: the chemical fertilizer concentration is 0.6–1.2 g/L, the sand content is 1 g/L, and the value range of working pressure is 40–55 kPa.
In Fig. 6a, the average relative flow of the H3-type drip irrigation tape decreased by 1.97%. It can be seen from Fig. 6b that under the condition of a chemical fertilizer concentration of 0.6 g/L the average relative flow rate decreases rapidly with increasing sediment content, i.e., by 28.57%. The maximum average relative flow rate is reached in the range of sediment content of 1.0–1.6 g/L. Under the condition of a chemical fertilizer concentration of 0.6 g/L, the pressure change has no effect on the average relative flow. In Fig. 6c, the average relative flow decreased by 35.13%. The average relative flow rate decreased by 10.03% in the range of pressure fertilizer concentration of 0.6–3.0 g/L. Under the condition of pressure of 40 kPa, the effect of sediment content on the average relative flow is more significant than that of chemical fertilizer concentration. From the comprehensive graph and analysis, it can be seen that the optimal operating conditions are as follows: of the chemical fertilizer concentration is 0.6–1.2 g/L, the pressure is 40 kPa, and the sand content is 1.0–1.2 g/L.
To summarize, there is an optimal combination of three factors in the ranges of chemical fertilizer concentration of 0.6–1.2 g/L, of sand content of 1.0–1.2 g/L, and of working pressure of 40–55 kPa. The calculation results of the PPR optimization simulation are shown in Table 8.
When the average relative flow rate is set to 0.75 to judge whether blockage occurs, it can be seen from the analysis of the average relative flow PPR model that the H1-type and H2-type have not yet reached the blockage standard, while the H3-type has reached a serious degree of blockage. In the actual project, the high sediment content is concentrated in the flood season29. In this experiment, under the irrigation conditions of high sediment content and high chemical fertilizer concentration, the clogging standard is still not reached after the ninth irrigation. Therefore, actual irrigation conditions are more difficult than the test conditions. When the muddy water sediment content is not less than 1 g/L, the fertilizer concentration should be controlled at approximately 0.6 g/L, which is consistent with Li’s research results38. When the control working pressure is 40 kPa, the rated flow of the H1-type is the smallest (1.8 L/h) among the three types of drip irrigation belts, which indicates the technical feasibility of low pressure and small flow. In addition, the maximum average relative flow can be obtained, which greatly reduces the engineering and operation costs of drip irrigation, facilitating the promotion and application of drip irrigation technology.
According to the PPR contour map in Figs. 4, 5, and 6, the three influencing factors of the average relative flow of the three drip irrigation belts can also be ranked. These results were consistent with the results of the variance analysis and the weight coefficient of a ridge function. The flow index of H1-type, H2-type and H3-type are 0.60, 0.61 and 0.55, respectively. The smaller the operating pressure sensitivity, the smaller the flow index, and the better the hydraulic performance. From the PPR contour map, it can be seen that H1-type and H2-type have little difference in sensitivity to operating pressure, and H3-type is the least sensitive to operating pressure, so H3-type has the best hydraulic performance. It can be seen from Figs. 4, 5 and 6 that the average relative flow of H1-type, H2-type and H3-type are negatively correlated with the concentration of chemical fertilizers, and the average relative flow of H1-type and H2-type have a negative correlation with operating pressure and sand content. But, the average relative flow of the H3-type is positively correlated with the operating pressure and sand content, which is caused by the difference in structure. The flow coefficients of H1-type, H2-type and H3-type are 0.11, 0.16, and 0.25, respectively. The better the combination of structural parameters, the greater the flow coefficient, and the better the hydraulic performance. According to the analysis, the sensitivity of H1-type, H2-type and H3-type to fertilizer concentration and sediment content is ranked as H1-type > H2-type > H3-type. The tooth spacing and the number of runner units have a positive correlation with the flow coefficient40. The tooth spacing and the number of runner units of H3-type are the largest, so the hydraulic performance of H3-type is better. The rated flow rates of H1-type, H2-type and H3-type are 1.8, 2.6 and 3.2 g/L respectively, and the flow rate is positively correlated with the flow coefficient.
To sum up, in the case of low pressure, low chemical fertilizer concentration, and low sand content, the H1-type is selected, which is conducive to the promotion of low pressure and small flow technology. In the case of high pressure, high chemical fertilizer concentration and high sand content, H3-type should be used to avoid blockage.
If you want to learn more, please visit our website Pressure Compensating Drip Tape.
Comments
0